How do gauss meter calibration? How to test? _ ndfeb strong magnet manufacturers

by:Newland     2020-04-05
Gauss meter is usually used to test some of the magnetic flux instrument. In order to choose the right product, what we need to know about the gauss meter calibration? Detection method is? Gauss meter daily maintenance and maintenance have? The following show you know one by one. The accuracy of gauss meter with standard magnets. Standard magnets is suitable for digital tesla's plan, Gauss meter) Probe the single point calibration, monitoring digital tesla's plan at any time, Gauss meter) Whether the working state of normal, flat on the table, the standard magnet hole who respond to our positive operation, probe alignment hole in a hole, probe into the mobile, always at the end ( Standard magnets co. , LTD. ) , slightly rotating or moving the probe, make digital tesla's plan, Gauss meter) Readings for the biggest, remember the maximum value, the maximum value and standard of magnet magnetic field between the size of the adjustment of digital tesla's plan ( Gauss meter) Calibration of digital tesla's plan, Gauss meter) A maximum of reading and standard magnets, magnetic field values are equal, digital tesla's plan, Gauss meter) Calibration and monitoring. What is the standard of magnet? Standard magnets is suitable for digital tesla's plan, Gauss meter) Probe the single point calibration, monitoring digital tesla's plan at any time, Gauss meter) Whether the working state of normal, easy to carry, simple to use. Please see below the magnet manufacturers usually how long will it take for testing a gauss meter? Gauss meter is usually six months or a year, concrete can be used according to the state to decide. Gauss meter to maintenance and repair: 1) Can't do STH without authorization to repair of high si meter, remove and transformation. 2) Use provisions within the scope of the power supply: ban and beyond the prescribed scope of power supply connection. 3) It is forbidden to high, and form a complete set of sensor drops or give a strong impact on the ground. 4) Ban the touch sensor probe and apex. Strictly prohibited for sensor heating, coating adhesive, adhesive tape, etc. 5) In direct sunlight. High temperature high humidity, water, oil, dust, corrosive air, vibration and so on high, is strictly prohibited. 6) Strictly abide by using temperature range and temperature range. 7) Ban prevent dewing phenomenon occurring in the gauss meter surface ( From the cold place rapidly transferred to a warm place) When using gauss meter. 8) It is forbidden to gauss meter placed in the machine of the magnetic fields: especially the charger/demagnetization machine/microwave/welding machine/motor, etc. That is about the magnet gauss meter calibration method, what kind of test? And testing cycle, compiled by ndfeb strong magnet manufacturer, to learn more magnets, new on this site.
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...